RampMetering.java
package org.opentrafficsim.road.network.control.rampmetering;
import org.opentrafficsim.core.dsol.OtsSimulatorInterface;
import nl.tudelft.simulation.dsol.SimRuntimeException;
/**
* Ramp metering. This consist of a {@code RampMeteringSwitch} and a {@code RampMeteringLightController}.
* <p>
* Copyright (c) 2013-2024 Delft University of Technology, PO Box 5, 2600 AA, Delft, the Netherlands. All rights reserved. <br>
* BSD-style license. See <a href="https://opentrafficsim.org/docs/license.html">OpenTrafficSim License</a>.
* </p>
* @author <a href="https://github.com/averbraeck">Alexander Verbraeck</a>
* @author <a href="https://tudelft.nl/staff/p.knoppers-1">Peter Knoppers</a>
* @author <a href="https://github.com/wjschakel">Wouter Schakel</a>
*/
public class RampMetering
{
/** Simulator. */
private final OtsSimulatorInterface simulator;
/** Ramp metering switch. */
private final RampMeteringSwitch rampSwitch;
/** Ramp metering light controller. */
private final RampMeteringLightController rampLightController;
/**
* @param simulator OtsSimulatorInterface; simulator
* @param rampSwitch RampMeteringSwitch; ramp metering switch
* @param rampLightController RampMeteringLightController; ramp metering light controller
*/
public RampMetering(final OtsSimulatorInterface simulator, final RampMeteringSwitch rampSwitch,
final RampMeteringLightController rampLightController)
{
this.simulator = simulator;
this.rampSwitch = rampSwitch;
this.rampLightController = rampLightController;
control();
}
/**
* Executes control in a cyclic manner.
*/
private void control()
{
if (this.rampSwitch.isEnabled())
{
this.simulator.getLogger().always().info("Ramp-metering enabled.");
this.rampLightController.enable(this.rampSwitch.getCycleTime());
}
else
{
this.simulator.getLogger().always().info("Ramp-metering disabled.");
this.rampLightController.disable();
}
try
{
this.simulator.scheduleEventRel(this.rampSwitch.getInterval(), this, "control", null);
}
catch (SimRuntimeException exception)
{
throw new RuntimeException("Interval from ramp metering switch is not a valid positive duration.", exception);
}
}
}